AF26-40-00-13 100-250V50/60HZ-DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF26-40-00-13 100-250V50/60HZ-DC Contactor

ABB

  • AF26-40-00-13

  • 1SBL237201R1300

  • Contactor - 4P


Unit price: $ 57.53

Total price: * This price is per unit and is the net value (not including taxes if applicable).


More Info



Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    45 mm
    Product Net Depth / Length:
    101 mm
    86 mm
    Product Net Weight:
    0.36 kg

    Technical

    • Number of Main Contacts NO:
      4
    • Number of Main Contacts NC:
      0
    • Number of Auxiliary Contacts NO:
      0
    • Number of Auxiliary Contacts NC:
      0
    • Standards:
      IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
    • Rated Operational Voltage:
      Main Circuit 690 V
    • Rated Frequency (f):
      Main Circuit 50 / 60 Hz
    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 °C 55 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 °C 45 A
      (690 V) 60 °C 40 A
      (690 V) 70 °C 32 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 60 °C 23.2 A
      (380 / 400 V) 60 °C 22 A
      (415 V) 60 °C 21.2 A
      (440 V) 60 °C 20 A
      (500 V) 60 °C 17.6 A
      (690 V) 60 °C 10.5 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 5.5 kW
      (400 V) 11 kW
      (415 V) 11 kW
      (440 V) 11 kW
      (500 V) 11 kW
      (690 V) 9 kW
    • Rated Short-time Withstand Current (Icw):
      at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
      for 1 s -empty- A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
    • Rated Insulation Voltage (Ui):
      acc. to UL/CSA 600 V
      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    • Rated Impulse Withstand Voltage (Uimp):
      6 kV
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
      50 Hz 100 ... 250 V
      60 Hz 100 ... 250 V
      DC Operation 100 ... 250 V
    • Operate Time:
      Between Coil De-energization and NC Contact Closing 13 ... 98 ms
      Between Coil De-energization and NO Contact Opening 11 ... 95 ms
      Between Coil Energization and NC Contact Opening 38 ... 90 ms
      Between Coil Energization and NO Contact Closing 40 ... 95 ms
    • Connecting Capacity Main Circuit:
      Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
      Flexible with Insulated Ferrule 2x 1.5 ... 16 mm²
      Flexible with Ferrule 1/2x 1.5 ... 16 mm²
      Rigid 1/2x 1.5 ... 16 mm²
    • Connecting Capacity Control Circuit:
      Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Rigid 1/2x 1 ... 2.5 mm²
    • Wire Stripping Length:
      Control Circuit 10 mm
      Main Circuit 12 mm
    • Degree of Protection:
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
    • Terminal Type:
      Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60 ... +80 °C
    Near Contactor for Operation in Free Air -40 ... +70 °C
  • Climatic Withstand:
    Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5 ... 300 Hz 4 g closed position / 2 g open position
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: B1 25 g
    Open, Shock Direction: B1 5 g
    Shock Direction: A 30 g
    Shock Direction: B2 15 g
    Shock Direction: C1 25 g
    Shock Direction: C2 25 g
  • RoHS Status:
    Following EU Directive 2011/65/EU

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 45 A
  • Tightening Torque UL/CSA:
    Control Circuit 11 in·lb
    Main Circuit 22 in·lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    87 mm
  • Package Level 1 Depth / Length:
    103 mm
  • Package Level 1 Height:
    47 mm
  • Package Level 1 Gross Weight:
    0.36 kg
  • Package Level 1 EAN:
    3471523115231
  • Package Level 2 Units:
    36 piece
  • Package Level 2 Width:
    250 mm
  • Package Level 2 Depth / Length:
    300 mm
  • Package Level 2 Height:
    315 mm
  • Package Level 2 Gross Weight:
    12.96 kg
  • Package Level 3 Units:
    864 piece

Classifications

  • Object Classification Code:
    Q
  • E-nummer:
    3211511
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • ETIM 7:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529

;