AF12-30-10-13 100-250V50/60HZ-DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF12-30-10-13 100-250V50/60HZ-DC Contactor

ABB

  • AF12-30-10-13

  • 1SBL157001R1310

  • Contactor - 3P


Unit price: $ 31.38

Total price: * This price is per unit and is the net value (not including taxes if applicable).


More Info



Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    45 mm
    Product Net Depth / Length:
    77 mm
    86 mm
    Product Net Weight:
    0.27 kg

    Technical

    • Number of Main Contacts NO:
      3
    • Number of Main Contacts NC:
      0
    • Number of Auxiliary Contacts NO:
      1
    • Number of Auxiliary Contacts NC:
      0
    • Standards:
      IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
    • Rated Operational Voltage:
      Auxiliary Circuit 690 V
      Main Circuit 690 V
    • Rated Frequency (f):
      Auxiliary Circuit 50 / 60 Hz
      Main Circuit 50 / 60 Hz
    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
      acc. to IEC 60947-5-1, q = 40 °C 16 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 °C 28 A
      (690 V) 60 °C 28 A
      (690 V) 70 °C 24 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 60 °C 12 A
      (380 / 400 V) 60 °C 12 A
      (415 V) 60 °C 12 A
      (440 V) 60 °C 12 A
      (500 V) 60 °C 12.5 A
      (690 V) 60 °C 9 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 3 kW
      (380 / 400 V) 5.5 kW
      (400 V) 5.5 kW
      (415 V) 5.5 kW
      (440 V) 5.5 kW
      (500 V) 7.5 kW
      (690 V) 7.5 kW
    • Rated Operational Current AC-15 (Ie):
      (220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (400 / 440 V) 3 A
      (500 V) 2 A
      (690 V) 2 A
    • Rated Short-time Withstand Current (Icw):
      at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
      for 0.1 s 140 A
      for 1 s 100 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
      AC-15 1200 cycles per hour
      AC-2 / AC-4 300 cycles per hour
      AC-3 1200 cycles per hour
      DC-13 900 cycles per hour
    • Rated Operational Current DC-13 (Ie):
      (110 V) 0.55 A / 60 W
      (220 V) 0.27 A / 60 W
      (400 V) 0.15 A / 60 W
      (500 V) 0.13 A / 65 W
      (600 V) 0.1 A / 60 W
      (125 V) 0.55 A / 69 W
      (24 V) 6 A / 144 W
      (250 V) 0.27 A / 68 W
      (48 V) 2.8 A / 134 W
      (72 V) 1 A / 72 W
    • Rated Insulation Voltage (Ui):
      acc. to UL/CSA 600 V
      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    • Rated Impulse Withstand Voltage (Uimp):
      6 kV
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
      50 Hz 100 ... 250 V
      60 Hz 100 ... 250 V
      DC Operation 100 ... 250 V
    • Operate Time:
      Between Coil De-energization and NC Contact Closing 13 ... 98 ms
      Between Coil De-energization and NO Contact Opening 11 ... 95 ms
      Between Coil Energization and NC Contact Opening 38 ... 90 ms
      Between Coil Energization and NO Contact Closing 40 ... 95 ms
    • Connecting Capacity Main Circuit:
      Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
      Flexible with Ferrule 1/2x 0.75 ... 6 mm²
      Rigid 1/2x 1 ... 6 mm²
    • Connecting Capacity Auxiliary Circuit:
      Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Rigid 1/2x 1 ... 2.5 mm²
    • Connecting Capacity Control Circuit:
      Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Rigid 1/2x 1 ... 2.5 mm²
    • Wire Stripping Length:
      Auxiliary Circuit 10 mm
      Control Circuit 10 mm
      Main Circuit 10 mm
    • Degree of Protection:
      acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
    • Terminal Type:
      Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60 ... +80 °C
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
    Close to Contactor without Thermal O/L Relay -40 ... +70 °C
  • Climatic Withstand:
    Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5 ... 300 Hz 4 g closed position / 2 g open position
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: B1 25 g
    Open, Shock Direction: B1 5 g
    Shock Direction: A 30 g
    Shock Direction: B2 15 g
    Shock Direction: C1 25 g
    Shock Direction: C2 25 g

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 28 A
  • Horsepower Rating UL/CSA:
    (120 V AC) Single Phase 1 Hp
    (240 V AC) Single Phase 2 Hp
    (200 ... 208 V AC) Three Phase 3 Hp
    (220 ... 240 V AC) Three Phase 3 Hp
    (440 ... 480 V AC) Three Phase 7-1/2 Hp
    (550 ... 600 V AC) Three Phase 10 Hp
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 11 in·lb
    Control Circuit 11 in·lb
    Main Circuit 13 in·lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    87 mm
  • Package Level 1 Depth / Length:
    79 mm
  • Package Level 1 Height:
    47 mm
  • Package Level 1 Gross Weight:
    0.27 kg
  • Package Level 1 EAN:
    3471523110335
  • Package Level 2 Units:
    54 piece
  • Package Level 2 Width:
    250 mm
  • Package Level 2 Depth / Length:
    300 mm
  • Package Level 2 Height:
    315 mm
  • Package Level 2 Gross Weight:
    14.58 kg
  • Package Level 3 Units:
    1296 piece

Classifications

  • Object Classification Code:
    Q
  • E-nummer:
    3211364
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • ETIM 7:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529

;