AF305-30-11-13 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF305-30-11-13 Contactor

ABB

  • AF305-30-11-13

  • 1SFL587002R1311

  • Contactor - 3P


Unit price: $ 1,081.95

Total price: * This price is per unit and is the net value (not including taxes if applicable).


More Info



Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    140.0 mm
    Product Net Depth / Length:
    180.0 mm
    225.0 mm
    Product Net Weight:
    4.640 kg

    Technical

    • Number of Main Contacts NO:
      3
    • Number of Main Contacts NC:
      0
    • Number of Auxiliary Contacts NO:
      1
    • Number of Auxiliary Contacts NC:
      1
    • Rated Operational Voltage:
      Main Circuit 1000 V
    • Rated Frequency (f):
      Main Circuit 50/60 Hz
    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 55 °C 400 A
      (690 V) 40 °C 500 A
      (1000 V) 40 °C 375 A
      (1000 V) 55 °C 325 A
      (690 V) 70 °C 325 A
      (1000 V) 70 °C 260 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 55 °C 305 A
      (380 / 400 V) 55 °C 305 A
      (415 V) 55 °C 305 A
      (440 V) 55 °C 305 A
      (500 V) 55 °C 290 A
      (690 V) 55 °C 290 A
      (1000 V) 55 °C 131 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 90 kW
      (380 / 400 V) 160 kW
      (415 V) 160 kW
      (440 V) 160 kW
      (500 V) 200 kW
      (690 V) 250 kW
      (1000 V) 185 kW
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
      8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Short-Circuit Protective Devices:
      gG Type Fuses 500 A
    • Rated Short-time Withstand Current (Icw):
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A
    • Maximum Electrical Switching Frequency:
      AC-3 300 cycles per hour
      AC-1 300 cycles per hour
      AC-2 / AC-4 150 cycles per hour
    • Rated Operational Current DC-1 (Ie):
      (110 V) 1-Pole, 40 °C 500 A
      (220 V) 2 Poles in Series, 40 °C 500 A
      (220 V) 3 Poles in Series, 40 °C 500 A
    • Rated Operational Current DC-3 (Ie):
      (110 V) 2 Poles in Series, 40 °C 400 A
      (220 V) 3 Poles in Series, 40 °C 400 A
    • Rated Operational Current DC-5 (Ie):
      (110 V) 2 Poles in Series, 40 °C 400 A
      (220 V) 3 Poles in Series, 40 °C 400 A
    • Rated Insulation Voltage (Ui):
      acc. to UL/CSA 600 V
      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    • Rated Impulse Withstand Voltage (Uimp):
      Main Circuit 8 kV
    • Mechanical Durability:
      5 million
    • Maximum Mechanical Switching Frequency:
      300 cycles per hour
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
    • Rated Control Circuit Voltage (Uc):
      60 Hz 100 ... 250 V
      50 Hz 100 ... 250 V
      DC Operation 100 ... 250 V
    • Coil Consumption:
      Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
      Holding at Max. Rated Control Circuit Voltage DC 4.5 W
      Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
      Pull-in at Max. Rated Control Circuit Voltage DC 410 W
      Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
      Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
    • Operate Time:
      Between Coil De-energization and NO Contact Opening 37 ... 47 ms
      Between Coil Energization and NO Contact Closing 25 ... 55 ms
    • Connecting Capacity Main Circuit:
      Rigid Al-Cable 1 x 185 ... 240 mm²
      Flexible 1 x 16 ... 240 mm²
      Rigid Cu-Cable 2 x 70 ... 185 mm²
    • Connecting Capacity Auxiliary Circuit:
      Solid 2 x 1 ... 4 mm²
      Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
      Stranded 1 x 1 .... 4 mm²
      Flexible 1x0.75 ... 2.5 mm²
      Flexible with Ferrule 1 x 0.75 ... 2.5 mm²
    • Degree of Protection:
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
    • Terminal Type:
      Main Circuit: Bars

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
    Close to Contactor for Storage -40 ... +70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • General Use Rating UL/CSA:
    (600 V AC) 400 A
  • Horsepower Rating UL/CSA:
    (208 V AC) Three Phase 100 Hp
    (440 ... 480 V AC) Three Phase 250 Hp
    (550 ... 600 V AC) Three Phase 300 Hp
    (220 ... 240 V AC) Three Phase 125 Hp
    (200 V AC) Three Phase 100 Hp

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    223 mm
  • Package Level 1 Depth / Length:
    175 mm
  • Package Level 1 Height:
    270 mm
  • Package Level 1 Gross Weight:
    5.31 kg
  • Package Level 1 EAN:
    7320500481776

Classifications

  • Object Classification Code:
    Q
  • E-nummer:
    3210163
  • ETIM 4:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • ETIM 6:
    EC000066 - Power contactor, AC switching
  • ETIM 7:
    EC000066 - Power contactor, AC switching
  • UNSPSC:
    39121529

;